Related Experiment Video
Updated: Nov 10, 2025

Development of a More Sensitive and Specific Chromogenic Agar Medium for the Detection of Vibrio parahaemolyticus and Other Vibrio Species
Published on: November 8, 2016
Sensitively and quickly detecting Vibrio vulnificus by real time recombinase polymerase amplification targeted to
Peng Zhu1, Yan Cui2, Jianhu Pang1
1Hwa Mei Hospital, University of Chinese Academy of Sciences, Ningbo, China; Ningbo Institute of Life and Health Industry, University of Chinese Academy of Sciences, Ningbo, China; Key Laboratory of Diagnosis and Treatment of Digestive System Tumors of Zhejiang Province, Ningbo, China.
Abstract:
Vibrio vulnificus (V. vulnificus) is a Gram-negative bacterium living in warm and salty water. This marine bacterium could produce hemolysin (VVH), which often causes serious gastroenteritis or septicemia when people contact to seawater or seafood containing V. vulnificus. Timely diagnosis is regard as essential to disease surveillance. In this paper, we aimed at developing a quick and sensitive method for the detection of Vibrio vulnificus using real time recombinase polymerase amplification (real time RPA). Specific primers and an exo probe were designed on the basis of the vvhA gene sequence available in GenBank. Target DNA could be amplified and labeled with specific fluorophore within 20 min at 38 °C. The method exhibited a high specificity, only detecting Vibrio vulnificus and not showing cross-reaction with other bacteria. The sensitivity of this method was 2 pg per reaction (20 μL) for DNA, or 200 copies per reaction (20 μL) for standard plasmid. The detection limit (LOD) stated as the target level that would be detected 95% of the time and estimated was 1.58 × 102 copies by fit of the probit to the results of 8 replicates in different concentration. For quantitative analysis of the real time RPA, the second order polynomial regression was adopted in our study. The results showed the correlation coefficients were raised above 0.98, which suggested this model might be a better choice for the quantitative analysis of real time RPA compared to the routine linear regression model. For artificially contaminated plasma samples, Vibrio vulnificus could be detected within 16 min by real time RPA at concentration as low as 1.2 × 102 CFU/mL or 2.4 CFU per reaction (20 μL). Thus, the real time RPA method established in this study shows great potential for detecting Vibrio vulnificus in the research laboratory and disease diagnosis.

