Related Experiment Video
Updated: Nov 10, 2025

Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
Iron amendments minimize the first-flush release of pathogens from stormwater biofilters
Maryam Ghavanloughajar1, Annesh Borthakur1, Renan Valenca1
1Civil and Environmental Engineering, The University of California at Los Angeles, Los Angeles, CA, USA.
Abstract:
First flush or the first pore volume of effluent eluted from biofilters at the start of rainfall contributes to most pollution downstream because it typically contains a high concentration of bacterial pathogens. Thus, it is critical to evaluate designs that could minimize the release of bacteria during a period of high risk. In this study, we test the hypothesis of whether an addition of iron-based media to biofilter could limit the leaching of Escherichia coli (E. coli), a pathogen indicator, during the first flush. We applied E. coli-contaminated stormwater intermittently in columns packed with a mixture of sand and compost (70:30 by volume, respectively) and iron filings at three concentrations: 0% (control), 3%, and 10% by weight. Columns packed with a mixture of sand and iron (3% or 10%) without compost were used to examine the maximum capacity of iron to remove E. coli. In columns with iron, particularly 10% by weight, the leaching of E. coli during the first flush was 32% lower than the leaching from compost columns, indicating that the addition of iron amendments could decrease first-flush leaching of E. coli. We attribute this result to the ability of iron to increase adsorption and decrease growth during antecedent drying periods. Although the addition of iron filings increased E. coli removal, the presence of compost decreased the adsorption capacity: exposure of 1 g of iron filings to 1 mg of DOC reduces E. coli removal by 8%. The result was attributed to the alteration of the surface charge of iron and blocking of adsorption sites shared by E. coli and DOC. Collectively, these results indicate that the addition of sufficient amounts of iron media could decrease pathogen leaching in the first flush effluent and increase the overall biofilter performance and protect downstream water quality.
More Related Videos
09:23Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
Related Concept Videos
Coagulation
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Factors Affecting Solubility