Abstract:
Although the use of a classical Venturi tube for wet gas metering has been extensively studied in the literature, the use of an extended-throat Venturi (ETV) tube has rarely been reported since its first proposal by J. R. Fincke in 1999. The structure of an ETV is very simple, but due to the complexity of multiphase flow, its theoretical model has not been fully established yet. Therefore, in this paper theoretical models have been developed for the convergent and throat sections of an ETV, and the gradients of front and rear differential pressures are derived analytically. Several flowrate algorithms have been proposed and compared with the existing ones. Among them, the iteration algorithm is found to be the best. A reasonable explanation is provided for its performance. The relationship between the differential pressure gradient and the flowrate relative error is also studied, such that the relative error distributions varying with ETV measured flowrates can be derived. The gas flowrate error of ETV increases with the liquid content whilst the liquid flowrate error of ETV decreases with the liquid content, and the relative errors of liquid flowrate are generally 2 to 3 times larger than that of the gas flowrate. Finally, the ETV tends to be more accurate than the classical Venturi tube. The ETV can be designed more compact under the same signal intensity due to its significantly higher velocity in the throat section.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Bernoulli's Principle: Applications
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below:
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...