Related Experiment Video
Updated: Nov 10, 2025

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
Characteristic Features of Infrared Thermographic Imaging in Primary Raynaud's Phenomenon
Lotte Lindberg1, Bent Kristensen1, Jane F Thomsen2
1Department of Nuclear Medicine, Copenhagen University Hospital, Herlev Hospital, Borgmester Ib Juuls Vej 1, 2730 Herlev, Denmark.
Abstract:
Raynaud's phenomenon (RP) is characterized by the episodic whitening of the fingers upon exposure to cold. Verification of the condition is crucial in vibration-exposed patients. The current verification method is outdated, but thermographic imaging seems promising as a diagnostic replacement. By investigating patients diagnosed with RP, the study aimed at developing a simple thermographic procedure that could be applied to future patients where verification of the diagnosis is needed. Twenty-two patients with primary RP and 58 healthy controls were examined using thermographic imaging after local cooling of the hands for 1 min in water of 10°C. A logistic regression model was fitted with the temperature curve characteristics to convey a predicted probability of having RP. The characteristics time to end temperature and baseline temperature were the most appropriate predictors of RP among those examined (p = 0.004 and p = 0.04, respectively). The area under the curve was 0.91. The cut-off level 0.46 yielded a sensitivity and specificity of 82% and 86%, respectively. The positive and negative predictive values were 69% and 93%, respectively. This newly developed thermographic method was able to distinguish between patients with RP and healthy controls and was easy to operate. Thus, the method showed great promise as a method for verification of RP in future patients. Trial registration: ClinicalTrials.gov NCT03094910.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermosensation

