Related Experiment Video
Updated: Nov 10, 2025

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
Coarse-to-Fine Image Matching-Based Footprint Camera Calibration of the GF-7 Satellite
Lirong Liu1, Junfeng Xie1, Xinming Tang1
1Land Satellite Remote Sensing Application Center, MNR, Beijing 100048, China.
Abstract:
The GF-7 satellite is China's first high-resolution stereo mapping satellite that reaches sub-meter resolution, equipped with new-type payloads, such as an area array footprint camera that can achieve synchronization acquisition of laser spots. When the satellite is in space, the variation of camera parameters may occur due to launch vibration and environmental changes, and on-orbit geometric calibration thereby must be made. Coupled with the data from the GF-7 satellite, this paper constructs a geometric imaging model of the area array footprint camera based on the two-dimensional direction angle, and proposes a coarse-to-fine "LPM-SIFT + Phase correlation" matching strategy for the automatic extraction of calibration control points. The single-image calibration experiment shows that the on-orbit geometric calibration model of the footprint camera constructed in this paper is correct and effective. The matching method proposed is used to register the footprint images with the DOM (Digital Orthophoto Map) reference data to obtain dense control points. Compared with the calibration result using a small number of manually collected control points, the root mean square error (RMSE) of the residual of the control points is improved from half a pixel to 1/3, and the RMSE of the same orbit checkpoints in the image space is improved from 1 pixel to 0.7. It can be concluded that using the coarse-to-fine image matching method proposed in this paper to extract control points can significantly improve the on-orbit calibration accuracy of the footprint camera on the GF-7 satellite.
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Field Application of Global Positioning System
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Calibration Curves: Correlation Coefficient

