Siloxanes in Biogas: Approaches of Sampling Procedure and GC-MS Method Determination
1GP CHEM, Laboratory of Biogas Research and Analysis, Legionów 40a/3, 87-100 Toruń, Poland.
Abstract:
A new approach of siloxane sampling based on impinger, micro-impinger, adsorption on active carbon, and direct TedlarBag methods followed by gas chromatography-mass spectrometry (GC-MS) was developed for the analysis of three linear (L2-L4) and four cyclic (D3-D5) volatile methyl siloxanes (VMSs). Three kinds of organic liquid-medium characterized by different polarities, namely acetone, methanol, and d-decane as siloxanes trap were arranged in the experiment which is widely discussed below. Thus, the GC-MS equipped with SUPELCOWAX-10 capillary column was employed to perform monitoring of VMS content in the analyzed biogas samples originating from landfill, wastewater treatment plants, and agriculture biogas plants. In all samples that have undergone the analysis, cyclic and linear VMSs were found in quantities exceeding 107.9 and 3.8 mg/m3, respectively. Significant differences between siloxanes concentrations depending on biogas origin were observed. Moreover, the high range of linearity (0.1 to 70.06 mg/m3), low LoD (0.01 mg/m3), low LoQ (0.04 mg/m3), and high recovery (244.1%) indicate that the procedure and can be applied in sensitive analyses of silica biogas contaminants. In addition to the above, the impinger method of sampling performed better than active-carbon Tube and TedlarBag, particularly for quantifying low concentrations of siloxanes. Overall, the evaluation of sampling methods for biogas collection simplified the analytical procedure by reducing the procedural steps, avoiding the use of solvents, as well as demonstrated its applicability for the testing of biogas quality.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
08:00Author Spotlight: Standardizing the Development of Amine-Based Silica Composites as CO2 Adsorbents for Direct Air Capture
Published on: September 29, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...