Insights
Coronary angiography (CA) after transcatheter aortic valve implantation (TAVI) is generally successful, though right-sided CA poses more challenges. Self-expanding valves are linked to increased CA difficulty, while Society of Thoracic Surgery scores offer weak predictive value.
Area of Science:
- Cardiovascular Interventions
- Interventional Cardiology
- Cardiac Imaging
Background:
- Coronary angiography (CA) success rates post-transcatheter aortic valve implantation (TAVI) are variable.
- Understanding factors influencing CA difficulty after TAVI is crucial for procedural planning and patient outcomes.
Purpose of the Study:
- To investigate the difficulty, outcomes, and predictors of coronary angiography (CA) following transcatheter aortic valve implantation (TAVI).
Main Methods:
- An international multicenter retrospective cohort study included 96 patients undergoing TAVI and subsequent CA.
- Coronary angiography difficulty was graded, with patients categorized as "easy" or "difficult".
- Multivariate logistic regression identified predictors of difficult CA.
Main Results:
- Overall CA success rate was high (92%), with left CA being more successful than right CA.
- Patients with "difficult" CA had higher Society of Thoracic Surgery (STS) scores, smaller annulus perimeters, and greater use of self-expanding valves.
- Self-expanding valves were the strongest predictor of difficult CA (aOR 15.23), while STS score showed borderline predictive value (aOR 1.26).
Conclusions:
- Coronary angiography after TAVI demonstrates a high success rate, with right-sided procedures being more challenging.
- The use of self-expanding valves is a significant predictor of CA difficulty post-TAVI.
- Further research is needed to validate these hypothesis-generating findings.
Background:
The success rate of coronary angiography (CA) after transcatheter aortic valve implantation (TAVI) is variable. Our aim was to investigate CA difficulty, outcomes, and predictors of difficult CA after TAVI.
Method:
This was an international multicentric retrospective cohort study that included patients with TAVI and subsequent CA between January 2010 and December 2019. Difficulty with CA was graded as 1 (normal), 2 (partial engagement, complete vessel opacification), 3 (partial engagement, incomplete vessel opacification), and 4 (unsuccessful angiography). Patients were grouped as (a) "easy" (grade 1 for left and right) or (b) "difficult" (grade >1 for either). We compared baseline characteristics and outcomes, and performed multivariate logistic regression for predictors of difficult CA.
Results:
Of 96 patients included (mean age 77.4±8.7 years, 48 [50%] male), 88 (92%) had successful CA. Right CA was successful in 80 (83%) patients and left CA in 91 (95%) (p<0.0001). The "difficult" group (n=41 [43%]) had higher Society of Thoracic Surgery (STS) scores (7.6±4.9 vs 5.4±4.0; p=0.022), smaller annulus perimeters (72.4±5.4 mm vs 76.2±9.4 mm; p=0.049), greater use of self-expanding valves (83% vs 18%; p<0.0001), increased valve size (26.8±2.1 mm vs 25.6±3.0 mm; p=0.032), and increased oversizing for area (44.3%±17.4% vs 23.6%±22.0%; p=0.0002) and perimeter (17.5%±8.2% vs 7.1%±10.8%; p<0.0001). There was no difference in outcomes except for increased major bleeding (7.3% vs 0.0%; p=0.042). The strongest predictor for "difficult" CA was self-expanding valves when compared to balloon-expandable valves (adjusted odds ratio [aOR], 15.23; 95% confidence interval [CI], 2.27-102.40). Society of Thoracic Surgery score was borderline predictive (aOR, 1.26; 95% CI, 1.04-1.52).
Conclusions:
Our results show that after TAVI, CA success rate is high, right CA is more difficult than left, self-expanding valves predispose to difficult CA, and STS score weakly predicts difficult CA. This study is hypothesis-generating and more research is required to confirm these findings.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization IV: Nursing Management