Related Experiment Video
Updated: Nov 10, 2025

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
Published on: August 4, 2023
The impedance analysis of small intestine fusion by pulse source
Yifan Wang1, Kefu Liu1, Xiaowei Xiang1
1Department of Light Sources and Illuminating Engineering, and Academy for Engineering&Technology, Fudan University, Shanghai, 200433, China.
Abstract:
The radiofrequency-induced intestine fusion has been widely studied as an alternative for traditional suture in surgery, but fusion quality cannot be evaluated directly. Impedance measurement can evaluate fusion quality, but the relation between impedance and the fusion quality needs optimization for best results. The present study reports the optimum resistance of small intestine fusion. As the feedback signal, resistance was considered the indicator of the fusion completion for the device design of intestine fusion and an in-depth study of microstructure change. A self-design pulse source was used for the small intestine fusion with adjustable voltage, duty ratio, frequency and output time. A frequency of 440 kHz was set, whereas voltage, output time and compression pressure (CP) of the small intestine were independent variables. Different conditions of voltage, CP and time were investigated for achieving the highest burst pressure (BP) measured with a pressure gauge and a peristaltic pump. Each parameter of the equivalent circuit model was calculated by an experimental waveform. Hematoxylin-eosin staining of fusion samples was used for assessing the quality of fusion. The real-time current was measured and recorded during the fusion for the calculation of capacitance and resistance. The highest BP of 38.9 mmHg was achieved with a CP of 900 kPa, a voltage of 50 V and a time of 5 s. Finally, an optimum extracellular resistance range of 61.0-86.2 Ω was found as the optimum resistance for the end of fusion, thus indicating automatic fusion with the best fusion quality.
Related Concept Videos
Source Transformation for AC Circuits
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Impedance Combination
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...

