Related Experiment Video
Updated: Nov 10, 2025

Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
Published on: May 23, 2015
Frequency of complications and risk factors associated with computed tomography guided core needle lung biopsies
Serap Yucel1, Asli Tanrivermis Sayit2, Leman Tomak3
1From the Radiology Section, Mus State Hospital, Mus, Turkey.
Background:
Although transthoracic needle biopsy (TTNB) is an effective method for diagnosis of lung tumors, it has some complications. It is crucial to know the frequency and severity of the complications of TTNB and its risk factors in order to avoid them.
Objectives:
Evaluate the complications and risk factors of computed tomography guided core needle lung biopsies (CT-CNLB).
Design:
Prospective evaluation of complications.
Setting:
Single center in Turkey.
Patients And Methods:
For CT-CNLBs performed between October 2017 and March 2018, the complications of biopsies were noted and classified as major and minor based on guidelines of the Society of Interventional Radiology.
Main Outcome Measures:
The complications and risk factors for complications were evaluated.
Sample Size:
123 adult patients.
Results:
The most common complications were pulmonary hemorrhage (30.9%) and pneumothorax (22%). Increased overall pulmonary hemorrhage was observed with underlying emphysema (P=.022), non-peripheral location of the lesion (P<.001), increased needle pathway (P<.001), fissure penetration (P=.011), increased number of pleura penetrations (P=.024), prolonged needle time across pleura (P=.037), and decreased lesion size (P=.033). The pneumothorax rate increased with non-peripheral location of the lesion (P<.007), fissure penetration (P=.021), prolonged needle time across the pleura (P=.013), and decreased lesion size (P=.002). In the logistic regression analyses for he two most common complications, the only risk factor for both alveolar hemorrhage and pneumothorax was a non-peripheral location of the lesion (P<.001, OR=14.7, 95% CI=3.9-55.4 for alveolar hemorrhage) and (P=.001, OR=156.2, 95% CI =7.34-3324.7 for pneumothorax).
Conclusion:
Most common complications of CT-CNLB were pneumothorax and pulmonary alveolar hemorrhage with a 5.7% major complication rate. Choosing the shortest possible trans-pulmonary needle pathway minimizes the risk of complications.
Limitations:
Limited number of patients, absence of rare complications as death, air embolism, and needle tract seeding.
Conflict Of Interest:
None.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...