Assessment of normal reference values for thyroid uptake of technetium-99m pertechnetate in a Saudi population
Awad Alshahrani1,2,3, Gulam M Syed4, Altaf H Khan2
1From the Department of Medicine, National Guard Health Affairs, Riyadh, Saudi Arabia.
Background:
Thyrotoxicosis is a common medical problem. Thyroid nuclear imaging with either I123 or technetium-99m (Tc-99m) pertechnetate are used to determine the cause. Although I123 has been the standard technique, Tc-99m pertechnetate is now commonly used, acceptable and easier to perform. The commonly used normal value of Tc-99m pertechnetate is 1-4%, but lower normal values have been reported in different populations.
Objective:
Determine normal reference range of Tc-99m pertechne-tate thyroid uptake for thyroid scintigraphy in Saudi Arabia.
Design:
Retrospective, cross-sectional.
Setting:
Nuclear medicine service at tertiary care center in Riyadh.
Patients And Methods:
We used data from biochemically euthyroid patients who underwent a thyroid Tc-99m pertechnetate scan while having parathyroid scintigraphy for hyperparathyroidism between April 2009 to April 2019. Medical records and biochemical thyroid function tests were reviewed and Tc-99m pertechnetate thyroid uptake values were determined for each patient.
Main Outcome Measures:
Thyroid uptake of Tc-99m pertechne-tate in euthyroid patients.
Sample Size:
167 RESULTS: The mean and median uptake of Tc-99m pertechnetate in euthyroid patients were 0.86% and 1.0%, respectively, and the inter-quartile range was 0.0-1.0%. The normal reference range in the study population was 0.2-2%. Thyroid uptake inversely correlated with age in females (r=-0.37, P<.001), males (r=-0.46, P=.001), and for all patients (r=?0.39, P<.0001).
Conclusion:
The range for normal thyroid Tc-99m pertechnetate was lower than the standard 1-4% range. Moreover, uptake decreased with age. Further studies are needed to establish the normal age-adjusted uptake for the thyroid Tc-99m pertechnetate scan.
Limitations:
Single center and retrospective.
Conflict Of Interest:
None.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...