Related Experiment Video
Updated: Nov 10, 2025

A Filter-based Surface Enhanced Raman Spectroscopic Assay for Rapid Detection of Chemical Contaminants
Published on: February 19, 2016
A sensitive and fast approach for voltammetric analysis of bisphenol a as a toxic compound in food products using a
Firouzeh Hassani Moghadam1, Mohammad A Taher1, Hassan Karimi-Maleh2
1Department of Chemistry, Shahid Bahonar University of Kerman, Iran.
Abstract:
A sensitive and fast approach has been introduced for the voltammetric sensing of bisphenol A based on modification of a paste electrode with Pt-SWCNTs and 1-ethyl-3-methylimidazolium n-butylsulfate as a highly conductive binder. The new sensor was used to determine the concentration of bisphenol A in food products in I-V mode. The Pt-SWCNTs nanocomposite was synthesized through the polyol method and its morphology was evaluated by field emission scanning electron microscopy, transmission electron microscopy and energy-dispersive X-ray spectroscopy techniques. The determining factors influencing the sensing performance, i.e., pH and mediators used in the modification process were optimized in the first step and the results showed that at a pH of 7.0, a modified paste containing 9% (w:w) nanocomposite and 20% (v:v) 1-ethyl-3-methylimidazolium n-butylsulfate formed catalytic properties enhancing the oxidation signal of bisphenol A by 5.9 folds. Current density investigation clearly confirmed the conductivity of Pt-SWCNTs and 1-ethyl-3-methylimidazolium n-butylsulfate in the paste matrix. In addition, fabricated sensor showed considerable sensing behavior for bisphenol A in the concentration range of 0.5 nM-180 μM with a detection limit of 0.2 nM. In the final step, using standard addition technique, the ability of fabricated sensor for sensing bisphenol A in food products was evaluated, and the results confirmed improved performance of the modified electrodes.
More Related Videos
08:06The Use of a β-lactamase-based Conductimetric Biosensor Assay to Detect Biomolecular Interactions
Published on: February 1, 2018
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
High-Performance Liquid Chromatography: Types of Detectors