A procedure and device for determining complex material permittivity using the free-space resonance method

Lin Qin1, En Li1, Yunpeng Zhang1

  • 1School of Electronic Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China.

Related Concept Videos

Susceptibility, Permittivity and Dielectric Constant01:26

Susceptibility, Permittivity and Dielectric Constant

When placed in an external electric field, a dielectric material gets polarized. The charge density in the dielectric material is given by the sum of the bound and free charge densities, while the total charge density can also be written in terms of the total electric field. The bound charge density can be measured in terms of polarization, leading to the relationship between electric displacement and polarization.
2.1K
Electromagnetic Waves in Matter01:30

Electromagnetic Waves in Matter

Electromagnetic waves can travel in the vacuum as well as in matter. For example light, which is an electromagnetic wave, can travel through air, water, or glass.
Consider the electromagnetic wave passing through a dielectric medium. In such a case, Maxwell's equations get modified. In Ampere's law, ε0 , the dielectric permittivity of free space is replaced with ε, the permittivity of dielectric. Also, the vacuum permeability μ0 is replaced by the permeability of the medium, μ.
Furthermore,...
3.6K
Parallel Resonance01:23

Parallel Resonance

The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by:
347
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
898
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
467