Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Dual-mode auto-calibrating resistance thermometer: A novel approach with Johnson noise thermometry
1Physikalisch-Technische Bundesanstalt (PTB), Abbestraße 2-12, 10587 Berlin, Germany.
Abstract:
A dual-mode auto-calibrating resistance thermometer (DART) is presented. The novel DART concept combines in one instrument the fast and accurate resistance thermometry with the primary method of Johnson noise thermometry. Unlike previous approaches, the new thermometer measures the spectral density of the thermal noise in the sensing resistor directly in a sequential measurement procedure without using correlation techniques. A sophisticated data analysis corrects the thermometer output for both the parasitic effects of the sensor wiring and the amplifier current noise. The instrument features a highly linear low-noise DC coupled amplifier with negative feedback as well as an accurate voltage reference and reference resistor to improve the gain stability over time and ambient temperature. Therefore, the system needs only infrequent calibrations with electrical quantum standards and can be operated over long intervals and a wide temperature range without recalibration. A first prototype is designed for the industrially relevant temperature range of the IEC 60751 (-200 °C to +850 °C); a later extension of the measurement range is being considered. A proof-of-principle measurement with a calibrated Pt100 sensor at room temperature yielded an uncertainty of about 100 µK/K. The final device is expected to reach uncertainties of below 10 µK/K, suitable for accurate measurements of the difference between thermodynamic temperatures and temperatures traceable to the International Temperature Scale of 1990 (ITS-90).
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Constant Pressure Calorimetry
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...