Related Experiment Video
Updated: Nov 10, 2025

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
Published on: February 4, 2018
Q-band high-performance notch filters at 56 and 77 GHz notches for versatile fusion plasma diagnostics
M Nishiura1, T Shimizu1, S Kobayashi1
1National Institute for Fusion Science, 322-6 Oroshi-cho, Toki, Gifu 509-5292, Japan.
Abstract:
A six-pole Q-band waveguide filter with a notch frequency above the Q-band has been developed for plasma diagnostics. The previous paper [Nishiura et al., J. Instrum. 10, C12014 (2015)] reported that the notch frequency exists within the standard band. In this study, the newly required notch filter extends the function, which prevents a thorny wave from being mixed into an instrument beyond the standard bandwidth of the waveguide. The mode control technique for cavities realizes a deep and sharp filter shape for Q-band notch filters with 56 and 77 GHz notches, respectively. The former filter has an attenuation more than 50 dB at 56.05 GHz and a bandwidth of 1.1 GHz at -3 dB. The latter filter has an attenuation more than 55 dB at 76.95 GHz and a bandwidth of 1.6 GHz at -3 dB. The electron cyclotron emission imaging and the electron cyclotron emission (ECE) diagnostics for the Q-band implemented a pair of the fabricated filters and demonstrated the ECE measurement successfully in the intense stray radiation from a 56 GHz gyrotron.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview