Related Experiment Video
Updated: Nov 10, 2025

Fixation of Ultrasound Transducers for Spinal Cord Neuromodulation in Mice
Published on: August 1, 2025
Skin temperature changes after ultrasound-guided supra-inguinal fascia iliaca block: a prospective observational
Manabu Yoshimura1, Hiroko Shiramoto2, Mami Koga2
1Department of Anesthesiology, Ube Industries Central Hospital, 750 Nishikiwa, Ube City, Yamaguchi, 755-0151, Japan. manabu-ygc@umin.ac.jp.
Purpose:
Ultrasound-guided supra-inguinal fascia iliaca block (SFIB) is widely used as regional anesthesia of the hip and thigh. It is difficult to judge the blocking effect and the spreading local anesthesia. We hypothesize that the effect and spread of the block could be proven objectively by a rise in the temperature. In this prospective observational study, the broad regional rise in skin temperature of twenty patients who were scheduled for hip surgery was measured using an infrared thermographic camera at multiple intervals following ultrasound-guided SFIB.
Methods:
Infrared thermographic imaging of skin temperature at the femoral, obturator, and lateral femoral cutaneous nerve sites was performed before and at 5-min intervals after ultrasound-guided SFIB for up to 15-min post-injection. The primary outcomes are skin surface temperature. Sensory block was assessed immediately after the final infrared thermographic image acquisition using the cold test.
Results:
Compared to pre-injection baseline, temperature increased by 1.2 °C [95% confidence interval (CI) 0.4-2.0 °C] after 5 min, 1.2 °C (95% CI 0.4-2.0 °C) after 10 min, and 0.9 °C (95% CI 0.4-2.1°C) after 15 min. The cold test response was reduced in all cases at the femoral and lateral femoral cutaneous nerve sites and in 13 cases at the obturator nerve site. The sensitivity and specificity of the temperature increase to cold loss were 96% and 63%, respectively when we defined >0°C as the clinical threshold.
Conclusions:
Successful SFIB significantly enhanced skin temperature at the hip and thigh in all cases, suggesting that infrared surface thermography can be used as an objective assessment tool for adequate analgesia.
Trial Registration:
University Hospital Medical Information Network Clinical Trials Registry ( UMIN 000037866 ). Registered 31 August 2019.
More Related Videos
03:14Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
05:24Author Spotlight: Exploring the Initiation Mechanism of 'Three-Method and Three-Acupoint' Tuina Analgesia in Rats with Nerve Injury
Published on: January 26, 2024
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Imaging Studies II: Ultrasonography
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...