Filter media depth and its effect on the efficiency of Household Slow Sand Filter in continuous flow
Bárbara Luíza Souza Freitas1, Ulisses Costa Terin1, Natália de Melo Nasser Fava1
1Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense, 400, São Carlos, São Paulo, 13566-590, Brazil.
Abstract:
This study evaluated the impact of a 50% reduction of filter media depth in Household Slow Sand Filters (HSSFs) on continuous flow to remove physicochemical and microbiological parameters from river water. Furthermore, simple pre-treatment and disinfection processes were evaluated as additional treatments. Two filter models with different filtration layer depths were evaluated: a traditional one with 50 cm media depth (T-HSSF) and a compact one (C-HSSF) with 25 cm. HSSFs were fed with pre-treated river water (24-h water sedimentation followed by synthetic fabric filtration) for 436 days at a constant filtration rate of 0.90 m3 m-2 day-1 with a daily production of 48 L day-1. Sodium hypochlorite (2.0 mg L-1 of NaOCl 2.5% for 30 min) was used to disinfect the filtered water. Water samples were analysed weekly for parameters such as turbidity, organic matter, colour and E. coli, among others. Removal of protozoan cysts and oocysts by the HSSFs were also evaluated. After pretreatment, turbidity from the HSSF river water was reduced to 13.2 ± 14.6 NTU, allowing the filters to operate. Statistical analysis indicated no significant difference (p > 0.05) between T-HSSF and C-HSSF efficiencies in all evaluated parameters throughout operation time. Hence, media depth reduction did not hinder continuous HSSF performance for almost all the evaluated parameters. However, it may have affected Giardia cysts retaining, which passed through the thinner media on one evaluation day. Disinfection was effective in reducing remaining bacteria from filtered water; however, it was ineffective to inactivate protozoa. The reduction in the filtration layer did not affect the overall filtered water quality or quantity showing that a compact HSSF model may be a viable option for decentralized water treatment.
More Related Videos
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
10:48EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. I. Collection of Virus Samples
Published on: March 28, 2015
Related Concept Videos
Filtration
Uniform Depth Channel Flow
Energy Considerations in Open Channel Flow
Uniform Depth Channel Flow: Problem Solving
Gradually Varying Flow
Rapidly Varying Flow