Related Experiment Video
Updated: Nov 9, 2025

Non-invasive Imaging of Acute Allograft Rejection after Rat Renal Transplantation Using 18F-FDG PET
Published on: April 28, 2013
Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear
Hira Lal1, Anuradha Singh1, Raghunandan Prasad1
1Department of Radiology, Faculty of Health Sciences, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, India.
Background:
The use of computed tomography (CT) for estimation of split renal function (SRF) has been reported previously. However, most of these studies have small samples, and many do not account for the renal attenuation at CT.
Objective:
The aim of this study was to compare multidetector computed tomography (MDCT) volumetry-attenuation-based SRF with that obtained via Tc99m-diethylenetriaminepentaacetic acid (DTPA) renal scintigraphy in voluntary renal donors.
Methods:
Between January 2017 and January 2020, 526 voluntary renal donors were enrolled prospectively. All donors underwent contrast CT and DTPA scan before surgery. The semiautomatic region of interest (ROI) tool was applied slice by slice on axial CT images acquired in the arterial phase. The renal contour was drawn semiautomatically with mouse clicks around the renal parenchyma, and the renal volume was ascertained. Using renal volume and attenuation, SRF was determined and compared with results obtained at DTPA imaging.
Results:
The mean age was 44.91 ± 10.97 years (mean ± s.d.). There was no significant difference in SRF based on DTPA and MDCT volumetry for the left kidney (49.18% ± 3.40% vs. 49.15% ± 3.38%, p = 0.540) and for the right kidney (50.82% ± 3.40% vs. 50.86% ± 3.39%, p = 0.358). A very good correlation was observed between the two methods for the left kidney (r = 0.953, p = 0.000) and the right kidney (r = 0.955, p = 0.000). On simple linear regression analysis, 90.8% of DTPA SRF values for the left kidney and 91.3% of DTPA SRF values for the right kidney could be predicted correctly using the corresponding MDCT SRF values.
Conclusion:
MDCT volumetry-attenuation-derived estimation of SRF for living renal donors could be an alternative to renal scintigraphy-based SRF estimation.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Kidney Transplant I: Introduction
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration