Related Experiment Video
Updated: Jul 23, 2026

Use of a Hanging-weight System for Isolated Renal Artery Occlusion
Published on: July 19, 2011
Vascular access for renal replacement therapy among 459 critically ill patients: a pragmatic analysis of the
Nicolas Benichou1,2,3, Saïd Lebbah4, David Hajage4,5,6
1AP-HP, Hôpital Européen Georges Pompidou, Service de Néphrologie, 75015, Paris, France.
Background:
Vascular access for renal replacement therapy (RRT) is routine question in the intensive care unit. Randomized trials comparing jugular and femoral sites have shown similar rate of nosocomial events and catheter dysfunction. However, recent prospective observational data on RRT catheters use are scarce. We aimed to assess the site of RRT catheter, the reasons for catheter replacement, and the complications according to site in a large population of critically ill patients with acute kidney injury.
Patients And Methods:
We performed an ancillary study of the AKIKI study, a pragmatic randomized controlled trial, in which patients with severe acute kidney injury (KDIGO 3 classification) with invasive mechanical ventilation, catecholamine infusion or both were randomly assigned to either an early or a delayed RRT initiation strategy. The present study involved all patients who underwent at least one RRT session. Number of RRT catheters, insertion sites, factors potentially associated with the choice of insertion site, duration of catheter use, reason for catheter replacement, and complications were prospectively collected.
Results:
Among the 619 patients included in AKIKI, 462 received RRT and 459 were finally included, with 598 RRT catheters. Femoral site was chosen preferentially (n = 319, 53%), followed by jugular (n = 256, 43%) and subclavian (n = 23, 4%). In multivariate analysis, continuous RRT modality was significantly associated with femoral site (OR = 2.33 (95% CI (1.34-4.07), p = 0.003) and higher weight with jugular site [88.9 vs 83.2 kg, OR = 0.99 (95% CI 0.98-1.00), p = 0.03]. Investigator site was also significantly associated with the choice of insertion site (p = 0.03). Cumulative incidence of catheter replacement did not differ between jugular and femoral site [sHR 0.90 (95% CI 0.64-1.25), p = 0.67]. Catheter dysfunction was the main reason for replacement (n = 47), followed by suspected infection (n = 29) which was actually seldom proven (n = 4). No mechanical complication (pneumothorax or hemothorax) occurred.
Conclusion:
Femoral site was preferentially used in this prospective study of RRT catheters in 31 French intensive care units. The choice of insertion site depended on investigating center habits, weight, RRT modality. A high incidence of catheter infection suspicion led to undue replacement.
Related Concept Videos
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Continuous Renal Replacement Therapy
Hemodialysis I: Introduction
Acute Kidney Injury I: Introduction
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Acute Kidney Injury V: Interprofessional Care