Related Experiment Video
Updated: Nov 9, 2025

Author Spotlight: Unraveling the Impact of Mechanical Ventilation on Diaphragm Function and Patient Outcomes
Published on: November 3, 2023
Case Studies in Physiology: Physiological and clinical effects of temporary diaphragm pacing in two patients with
Elena Keough-Delgado1, Lucía López-Rodríguez1, Beatríz de Olaiz1
1Hospital Universitario de Getafe, Madrid, Spain.
Abstract:
Ventilator-induced diaphragm dysfunction (VIDD) is increasingly recognized as an important side-effect of invasive ventilation in critically ill patients and is associated with poor outcomes. Whether patients with VIDD benefit from temporary diaphragm pacing is uncertain. Intramuscular diaphragmatic electrodes were implanted for temporary stimulation with a pacing device (TransAeris System) in two patients with VIDD. The electrodes were implanted via laparoscopy (first patient) or via bilateral thoracoscopy (second patient). Stimulation parameters were titrated according to tolerance. Diaphragm thickening fraction by ultrasound, maximum inspiratory pressure (Pimax) and diaphragm electromyography (EMGdi) signal analysis were used to monitor the response to diaphragm pacing. Both patients tolerated diaphragm pacing. In the first patient, improvements in diaphragm excursions were noted once pacing was initiated and diaphragm thickening fraction did not further deteriorate over time. The diaphragm thickening fraction improved in the second patient, and Pimax as well as EMGdi analysis suggested improved muscle function. This patient could be fully weaned from the ventilator. These case reports present the first experience with temporary diaphragm pacing in critically ill patients with VIDD. Our results should be taken cautiously given the reduced sample size, but provide the proof of concept to put forward the hypothesis that a course of diaphragm pacing may be associated with improved diaphragmatic function. Our findings of the tolerance to the procedure and the beneficial physiological effects are not prove of safety and efficacy, but may set the ground to design and conduct larger studies.NEW & NOTEWORTHY Diaphragmatic electrode implantation and temporary diaphragm pacing have not been previously used in ICU patients with VIDD. Patients were monitored using a multimodal monitoring approach including ultrasound of the diaphragm, measurement of maximum inspiratory pressure and EMG signal analysis. Our results suggest that diaphragm pacing may improve diaphragmatic function, with the potential to prevent and treat VIDD in critically ill patients. Safety and efficacy of this intervention is yet to be proven in larger studies.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Respiratory Volumes and Capacities I
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:

