Related Experiment Video
Updated: Nov 9, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Automated versus manual oxygen control in preterm infants receiving respiratory support: a systematic review and
Mohamed Abdo1,2, Ahmed Hanbal2,3, Moamen Mostafa Asla2,4
1Faculty of Medicine, Assiut University, Assiut, Egypt.
Background:
Ventilated preterm infants are exposed to deviations from the intended arterial oxygen saturation range. Therefore, an automated control system was developed to rapidly modulate the fraction of inspired oxygen. The aim of this review is to compare the efficacy and safety of automated versus manual oxygen delivery control.
Methods:
In December 2020, we systematically searched four electronic databases; PubMed, Cochrane Library, Scopus, and Web of Science for eligible randomized controlled trials. We extracted and pooled data as mean difference and 95% confidence interval in an inverse variance method using RevMan software.
Results:
Thirteen trials were included in this systematic review and meta-analysis, enrolling 343 preterm infants on respiratory support. Automated oxygen control increased the time spent within the target arterial oxygen saturation range of 85-96% (MD = 8.96; 95% CI [6.26, 11.67], p<.00001), and 90-95% (MD = 18.25; 95% CI [4.58, 31.65], p = .008). In addition, it reduced the time of hypoxia (<80%); (MD = -1.24; 95% CI [-2.05, -0.43], p = .003), (MD = -0.82; 95% CI [-1.23, -0.41], p<.0001) with predetermined ranges of 85-96% and 90-95%, respectively. Automated control system reduced as well the time of hyperoxia (>98%) (MD = -0.99; 95% CI [-1.74, -0.25], p = .009) at intended range of 90-95%, and number of manual inspired oxygen fraction adjustments (MD = -2.82; 95% CI [-4.56, -1.08], p = .002).
Conclusions:
Automated oxygen delivery is rapid and effective in controlling infants' oxygen saturation. It can be used to reduce the load over the nurses, but not to substitute the clinical supervision. Further long-term trials of large-scale are required to evaluate the prolonged clinical outcomes.
Related Concept Videos
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...