Related Experiment Video
Updated: Nov 9, 2025

Symptom Assessment of Patients with Allergic Rhinitis Using an Allergen Exposure Chamber
Published on: March 3, 2023
Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure
1Department of Electronic Engineering, National Taipei University of Technology, No. 1 Sec. 3, Chung-Hsiao E. Rd., Taipei 10608, Taiwan.
Abstract:
In the beginning of 2020, the coronavirus (COVID-19) pandemic started to spread globally, causing panic to the lives of people around the world; many countries executed lockdown of cities or even total lockdown of the entire countries. The coronavirus disease (COVID-19) is transmitted via air droplets. In medical environments that use traditional hermetic ventilation systems, medical personnel who come in contact with patients are more susceptible to infection compared to regular staff; therefore, the air flow and air quality of hermetic negative pressure isolation wards are highly critical. For this purpose, the study proposes a full-outer-air-intake natural air-conditioning system for negative pressure isolation wards. This innovative system draws in large amounts of fresh external air to greatly improve the air exchange rate in wards; negative pressure environments can be implemented depending on requirements to solve the issue of nosocomial infections in traditional negative pressure isolation wards that draw air from within the hospital. This greatly reduces the probability of nosocomial infection and infection via air droplets; furthermore, the system's intake and exhaust paths are completely isolated, solving the issue of air cross-contamination. Based on the results from the experiment site, this innovative system was designed and implemented based on the guidelines of hospital facilities and achieved air exchange per hour in excess of 12 times/hour, reaching a maximum of 54.5 times/hour. Indoor CO2 concentration was 576 ppm, negative pressure was -14 Pa, indoor temperature was 23.3°C, indoor humidity was 54.1%, and sensible heat exchange efficiency (ηs) was 105.88% which effectively reduced ventilation load. Therefore, this innovative full-outer-air-intake natural air-conditioning system can provide medical staff and patients with a safe and healthy environment that prevents cross-infection.
More Related Videos
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...

