Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Mechanistic Models: Compartment Models in Individual and Population Analysis01:23

Mechanistic Models: Compartment Models in Individual and Population Analysis

137
Mechanistic models are utilized in individual analysis using single-source data, but imperfections arise due to data collection errors, preventing perfect prediction of observed data. The mathematical equation involves known values (Xi), observed concentrations (Ci), measurement errors (εi), model parameters (ϕj), and the related function (ƒi) for i number of values. Different least-squares metrics quantify differences between predicted and observed values. The ordinary least...
137

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Two models of the structures of the lamellae in human meibum and the tear film lipid layer, TFLL.

The ocular surface·2025
Same author

Prevalence Estimation Methods for Time-Dependent Antibody Kinetics of Infected and Vaccinated Individuals: A Markov Chain Approach.

Bulletin of mathematical biology·2025
Same author

Safety and Efficacy of Hydroxypropyl Guar-Hyaluronic Acid Dual-Polymer Lubricating Eye Drops in Indian Subjects with Dry Eye: A Phase IV Study.

Ophthalmology and therapy·2024
Same author

High Resolution Images of Human Meibum Spread on Saline.

Investigative ophthalmology & visual science·2024
Same author

Multi-symptom Relief with Propylene Glycol-Hydroxypropyl-Guar Nanoemulsion Lubricant Eye Drops in Subjects with Dry Eye Disease: A Post-Marketing Prospective Study.

Ophthalmology and therapy·2023
Same author

Modeling in higher dimensions to improve diagnostic testing accuracy: Theory and examples for multiplex saliva-based SARS-CoV-2 antibody assays.

PloS one·2023

Related Experiment Video

Updated: Nov 9, 2025

Author Spotlight: Isolating Biomolecules from Mouse Tears — A Methodology for Molecular Analysis and Biomarker Research
09:04

Author Spotlight: Isolating Biomolecules from Mouse Tears — A Methodology for Molecular Analysis and Biomarker Research

Published on: July 19, 2024

2.0K

Parameter Estimation for Mixed-Mechanism Tear Film Thinning.

Rayanne A Luke1, Richard J Braun2, Tobin A Driscoll2

  • 1Department of Mathematical Sciences, University of Delaware, Newark, DE, 19716, USA. rayanne@udel.edu.

Bulletin of Mathematical Biology
|April 9, 2021
PubMed
Summary

Tear breakup is driven by evaporation and lipid flow, often combined. Mathematical modeling of in vivo fluorescence data reveals these factors cooperate, leading to faster tear film breakup than evaporation alone.

Keywords:
Dry eyeFluorescence imagingOptimizationTear film

More Related Videos

Development of an In Vitro Ocular Platform to Test Contact Lenses
08:28

Development of an In Vitro Ocular Platform to Test Contact Lenses

Published on: April 6, 2016

10.9K
Bead Based Multiplex Assay for Analysis of Tear Cytokine Profiles
09:22

Bead Based Multiplex Assay for Analysis of Tear Cytokine Profiles

Published on: October 13, 2017

12.1K

Related Experiment Videos

Last Updated: Nov 9, 2025

Author Spotlight: Isolating Biomolecules from Mouse Tears — A Methodology for Molecular Analysis and Biomarker Research
09:04

Author Spotlight: Isolating Biomolecules from Mouse Tears — A Methodology for Molecular Analysis and Biomarker Research

Published on: July 19, 2024

2.0K
Development of an In Vitro Ocular Platform to Test Contact Lenses
08:28

Development of an In Vitro Ocular Platform to Test Contact Lenses

Published on: April 6, 2016

10.9K
Bead Based Multiplex Assay for Analysis of Tear Cytokine Profiles
09:22

Bead Based Multiplex Assay for Analysis of Tear Cytokine Profiles

Published on: October 13, 2017

12.1K

Area of Science:

  • Ophthalmology
  • Biophysics
  • Mathematical Modeling

Background:

  • Tear film breakup is crucial for ocular surface health.
  • Current understanding attributes tear breakup primarily to evaporation or divergent flow.
  • The role of lipid-driven tangential flow, potentially from lipid 'globs', is less understood.

Purpose of the Study:

  • To develop and apply a mathematical model to quantify tear breakup mechanisms.
  • To investigate the combined effects of evaporation and lipid-driven tangential flow on tear film stability.
  • To determine tear breakup parameters that are not directly measurable in vivo.

Main Methods:

  • Fitting a mathematical model of tear breakup, incorporating evaporation and lipid-driven tangential flow, to in vivo fluorescence imaging data.
  • Utilizing least squares minimization with trust-region-reflective or Levenberg-Marquardt algorithms for parameter estimation.
  • Comparing model-predicted fluorescent intensity with experimental data to determine key variables.

Main Results:

  • The study successfully determined tear breakup parameters, including evaporation and tangential flow rates, by fitting the mathematical model to experimental data.
  • Best-fit parameter estimations support the hypothesis that evaporation and divergent tangential flow cooperate in driving tear breakup.
  • Combined mechanisms result in significantly faster tear breakup compared to purely evaporative models.

Conclusions:

  • Tear film breakup is often a result of combined evaporative and divergent tangential flow mechanisms.
  • The presence of lipid excess, or 'globs', may contribute to lipid-driven tangential flow.
  • Considering multiple mechanisms provides a more comprehensive interpretation of in vivo experimental results for tear breakup.