Inter-rater variability in patch test readings and final interpretation using store-forward teledermatology
Related Experiment Video
Updated: Jul 30, 2026

Trans-vivo Delayed Type Hypersensitivity Assay for Antigen Specific Regulation
Published on: May 2, 2013
Molly C Goodier1,2, Joel G DeKoven3, James S Taylor4
1Department of Dermatology, Minneapolis Veterans Affairs Medical Center, Minneapolis, Minnesota, USA.
Background:
Data regarding teledermatology for patch testing are limited.
Objectives:
Compare patch test readings and final interpretation by two in-person dermatologists (IPDs) with eight teledermatologists (TDs).
Methods:
Patch tested patients had photographs taken of 70 screening series of allergens at 48 hours and second readings. Eight TDs reviewed photos and graded reactions (negative, irritant, doubtful, +, ++, +++) at 48 hours and second readings; in addition, they coded a final interpretation (allergic, indeterminant, irritant, negative) for each reaction. TDs rated overall image quality and confidence level for each patient and patch test reaction, respectively. Percentage of TD-IPD agreement based on clinical significance (success, indeterminate, and failure) was calculated. Primary outcome was agreement at the second reading.
Results:
Data were available for 99, 101, and 66 participants at 48 hours, second reading, and final interpretation, respectively. Pooled failure (+/++/+++ vs negative) at second reading was 13.6% (range 7.9%-20.4%). Pooled failure at 48 hours and final interpretation was 5.4% (range 2.9%-6.8%) and 24.6% (range 10.2%-36.8%), respectively. Confidence in readings was statistically correlated with quality of images and disagreement.
Conclusion:
For patch testing, teledermatology has significant limitations including clinically significant pooled failure percentages of 13.6% for second readings and 24.6% for final interpretation.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...

