Doppler echocardiographic estimation of cardiac output: analysis of temporal variability
S C Robson1, R J Boys, S Hunter
1Department of Paediatric Cardiology, Freeman Hospital, Newcastle Upon Tyne, U.K.
Abstract:
The temporal variability of combined cross-sectional and Doppler echocardiographic estimates of cardiac output was studied in 14 normal subjects. In each subject cross-sectional echocardiographs and Doppler velocities were recorded from the aortic, pulmonary and mitral valves. Recordings were repeated after 30-60 min and after 1-3 months to allow estimation of short-term and long-term temporal variability. A components of variance analysis showed that between-subject variability was significantly larger than within-subject variability for all measured and calculated variables. Long-term variability was larger than short-term variability for all variables except the mitral valve area. Calculation of flows from the three measurement sites were equally reproducible and the mean percentage error for CO measurements performed 1-3 months apart ranged from 6.4% to 7.4%. The 95% confidence intervals for Doppler measurements of CO at the three sites ranged from +/- 0.49 l min-1 to +/- 0.56 l min-1, suggesting that the temporal variability of flow measurements using the non-invasive Doppler method is sufficiently small for the method to be useful in serial haemodynamic studies.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
09:32Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
