Reference values for pulsed Doppler signals from the blood flow velocity on both sides of the pulmonary valve
A van Oort1, S de Knecht, I van Dam
1Interuniversity Cardiology Institute, Radboud University Hospital, Nijmegen, The Netherlands.
Abstract:
Pulsed Doppler signals were recorded from the pulmonary artery and the right ventricular outflow tract in 215 healthy subjects (120 males, 95 females; 1-65 years). Amplitude spectra from these Doppler signals were stored in digital form together with adjustment data for the instrument and the simultaneously recorded ECG. From these Doppler spectra the median of the maximal velocity (Vmax), the maximal acceleration (Amax) and the dispersion of the velocity distribution around Vmax (width) were calculated. These three median values were used to characterize the Doppler spectra and to define normal values for bloodflow velocities. Thus, calculations were made without observer interacting using a well-defined computer program. The effect of age, gender, body surface area and heart rate were studied. Reference ranges were calculated. There is a slight decrease of the median value of Vmax and Amax in the pulmonary artery during lifetime from 80 to 70 cm s-1 and from 1,200 to 800 cm s-2, respectively. On the other hand, there is no correlation between age and Vmax and Amax in the right ventricular outflow tract. The width of the spectra increases with age at both sites. No significant changes with age were seen with the other variables.
More Related Videos
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Blood Pressure
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical...