Related Experiment Video
Updated: Nov 9, 2025

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
An improved strategy for analysis of lipid molecules utilising a reversed phase C30 UHPLC column and scheduled MS/MS
Andris Jankevics1, Amelia Jenkins2, Warwick B Dunn3
1School of Biosciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, United Kingdom; Phenome Centre Birmingham, University of Birmingham, Edgbaston, Birmingham, B15 2TT, United Kingdom.
Abstract:
Measuring physiochemically diverse molecules (including lipids) which vary significantly in their concentrations poses a great analytical challenge. In untargeted lipidomics studies, reversed phase chromatography coupled with data-dependent MS/MS acquisition (DDA) is frequently applied. The optimal assay should deliver a high number of detected compounds with associated fragmentation data. In this work, we introduce novel 30 and 50 min UHPLC assays utilising lipid separation on a C30 stationary phase with a modified DDA strategy using smaller precursor m/z ranges scheduled for different lipid classes across the retention time range (defined as scheduled MS/MS). To evaluate the efficiency of the novel assays, mammalian tissue extracts (lamb liver, kidney and heart) were analysed and data were compared to a 15 min reversed phase C18 assay with multiple traditional DDA injections. The 30 min C30 assay detected double the number of detected compounds compared to the 15 min C18 assay. Applying the scheduled MS/MS DDA strategy with a single injection, a similar number of annotated lipids were reported compared to the traditional DDA strategy applied with five replicate injections on a C18 column. A longer 50 min C30 chromatographic assay did not result in an expected improvement in the chromatographic separation of overlapping isomer peaks compared to the 30 min method but did result in loss of accuracy of peak picking algorithms. We recommend the 30 min C30 assay with scheduled MS/MS acquisition as an efficient tool to analyse complex biological matrices and to annotate lipid species based on MS/MS data.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation