Cryogenic trapping as a versatile approach for sample handling, enrichment and multidimensional analysis in gas
Fábio Junior Moreira Novaes1, Philip John Marriott2
1Universidade Federal de Viçosa, Departamento de Química, Avenida Peter Henry Rolfs, s/n, Viçosa, MG 36570-900, Brazil; Universidade Federal do Rio de Janeiro, Instituto de Química, Programa de Pós-Graduação em Química, Avenida Athos da Silveira Ramos, 149, Bloco A, 6° Andar, Sala 626, Rio de Janeiro, RJ 21941-909, Brazil.
Abstract:
Cryogenic methods - those that employ cryogenic fluids/gases but also other approaches to generate reduced temperature - are versatile, functional and relatively easily implemented as part of a total gas chromatographic method. The general utility of a cold region is almost invariably as a trapping or focussing step, to collect analyte into a sharp zone. The success in effectively trapping analyte depends on analyte volatility and the temperature of the cold region. Analytes collection into a sorbent phase supported by cryotrapping usually provide a greater capacity trapping for the sorption step. Stripping analyte from a sample into a cryogenic trap, with subsequent introduction to GC as in a purge-and-trap method, sample introduction into an injector with incorporation of a cooling zone, manipulation and management of chromatographic bands during chromatography elution such as employed in multidimensional gas chromatography, and focussing analyte just prior to the detector, all have the same goal of concentrating the band, reducing its dispersion, and maximising response. This review summarises various approaches that demonstrate how cryogenic methods have been incorporated into gas chromatographic analysis.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...