Related Experiment Video
Updated: Nov 9, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Feasibility of a second-generation colon capsule in visualization of the upper gastrointestinal tract
Gangping Li1, Yu Jin1, Tao Bai1
1Division of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Background:
Capsule endoscopy for visualization of the entire gastrointestinal tract is a challenge. A second-generation colon capsule endoscopy system (CCE-2) performed well in the colon and small intestine, but its utility in the upper gastrointestinal duct is not clear. We evaluated the use of the CCE-2 in the visualization of the upper gastrointestinal tract.
Methods:
We performed a retrospective study and further evaluated CCE-2 images using the typical landmarks of esophagus and stomach. The two imagers located at each end of the CCE-2 system were defined as imager1 (green) and imager2 (yellow). Two endoscopists read the images, and they were blinded to the other reader's results. All of the images from the two imagers were separately reviewed.
Results:
Images from 127 subjects were analyzed. This study demonstrated the comprehensive visualization of 71.7% of esophageal landmarks and 89.8% of gastric landmarks using the CCE-2. The two CCE-2 imagers were not identical, and the lighter imager (imager2, yellow) was superior to the heavier imager (imager1, green) (78% vs. 33.1%) in the stomach. Compared with the use of one imager, the use of two imagers was superior (two-imager vs. imager1, 89.8% vs. 33.1%; two-imager vs. imager2, 89.8% vs. 78%) in the stomach. Two-imager combination analysis detected a total of 160 positive findings. In contrast, single-imager analysis with imager1 and imager2 detected 133 and 137 findings, respectively. Two-imager combination analysis provided 20.3% and 16.8% more findings than imager1 and imager2, respectively. The two imagers complemented each other to detect more lesions.
Conclusions:
The CCE-2 system is feasible for use in the upper gastrointestinal tract and may be considered an optional tool for upper gastrointestinal imaging. This system may represent a good choice for complete gastrointestinal duct screening. Compared with the use of one imager, the two-imager combination provided improved upper gastrointestinal tract mucosal visualization.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...