A Retention-Matching Strategy for Method Transfer in Supercritical Fluid Chromatography: Introducing the Isomolar
Martin Enmark1, Jörgen Samuelsson1, Torgny Fornstedt1
1Department of Engineering and Chemical Sciences, Karlstad University, Karlstad SE-651 88, Sweden.
Abstract:
A strategy to match any retention shifts due to increased or decreased pressure drop during supercritical fluid chromatography (SFC) method transfer is presented. The strategy relies on adjusting the co-solvent molarity without the need to adjust the back-pressure regulator. Exact matching can be obtained with minimal changes in separation selectivity. To accomplish this, we introduce the isomolar plot approach, which shows the variation in molar co-solvent concentration depending on the mass fraction of co-solvent, pressure, and temperature, here exemplified by CO2-methanol. This plot allowed us to unify the effects of the co-solvent mass fraction and density on retention in SFC. The approach, which was verified on 12 known empirical retention models for each enantiomer of six basic pharmaceuticals, allowed us to numerically calculate the apparent retention factor for any column pressure drop. The strategy can be implemented either using a mechanistic approach if retention models are known or empirically by iteratively adjusting the co-solvent mass fraction. As a rule of thumb for the empirical approach, we found that the relative mass fraction adjustment needed is proportional to the relative change in the retention factor caused by a change in the pressure drop. Different proportionality constants were required to match retention in the case of increasing or decreasing pressure drops.
More Related Videos
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatographic Methods: Terminology
Analyte Adsorption and Distribution
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Elution Process