MANual vs. automatIC local activation time annotation for guiding Premature Ventricular Complex ablation procedures
Beatriz Jáuregui1, Juan Fernández-Armenta2, Juan Acosta3
1Heart Institute, Teknon Medical Center, C/Vilana, 12, 08022 Barcelona, Spain.
Summary
An automatic protocol for local activation time annotation significantly improves procedural efficiency during premature ventricular complex ablation, achieving similar clinical success rates compared to manual methods.
Area of Science:
- Cardiology
- Electrophysiology
- Medical Technology
Background:
- Premature ventricular complex (PVC) ablation procedures often rely on manual annotation of local activation time (LAT).
- Optimizing procedural efficiency is crucial for improving patient outcomes and resource utilization in electrophysiology labs.
Purpose of the Study:
- To evaluate the benefits of an automatic LAT acquisition protocol using wavefront annotation and ECG pattern matching (AUT-arm) in PVC ablation.
- To compare the procedural efficiency and success rates of the automatic protocol against conventional manual annotation (MAN-arm).
Main Methods:
- A prospective, randomized, controlled, international multicenter study enrolled 100 patients undergoing PVC ablation.
- Patients were randomized to either the automatic (AUT) or manual (MAN) LAT annotation protocol using the CARTO3 navigation system.
- Primary endpoint was mapping success; clinical success was defined as ≥80% PVC burden reduction at 6 months.
Main Results:
- The automatic protocol significantly reduced mapping and procedure times (P < 0.014) and increased acquired mapping points (P < 0.001).
- Both mapping and clinical success rates were similar between the AUT and MAN groups.
- No significant differences in radiofrequency time, RF applications, or procedure-related complications were observed.
Conclusions:
- The automatic LAT annotation protocol offers higher procedural efficiency in PVC ablation compared to manual methods.
- This automated approach achieves comparable clinical outcomes, demonstrating its potential as a valuable tool for electrophysiologists.
- The study supports the adoption of automated protocols to streamline PVC ablation procedures without compromising efficacy.