Related Experiment Video
Updated: Nov 9, 2025

Author Spotlight: Developing a Bedside Protocol for Kidney and Genitourinary Ultrasonography
Published on: June 21, 2024
Factors Affecting Patient Radiation Exposure During Prone and Supine Percutaneous Nephrolithotomy
Anna M Zampini1, Jacob N Bamberger1, Kasmira Gupta1
1Department of Urology, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Abstract:
Radiation exposure from fluoroscopy poses risks to patients and surgeons. Percutaneous nephrolithotomy (PCNL) has traditionally required fluoroscopy, however, the use of ultrasound (US) has decreased radiation exposure. US guidance in supine PCNL (S-PCNL) may further reduce radiation exposure. In this study, we investigate patient and operative factors affecting fluoroscopy time (second), total radiation dose (mGy), and effective dose (ED, mSv) in patients undergoing US-guided S-PCNL or prone PCNL (P-PCNL). We performed a retrospective study of patients undergoing US-guided PCNL in prone and supine positions. Patients with multiple access tracts, pre-existing renal access, or fluoroscopic renal access were excluded. Patient demographic and radiologic and operative data were collected, and compared between the two groups. Ninety-nine patients were included: 45 P-PCNL and 54 S-PCNL. There were no significant demographic differences between the two groups. Operative time, access location, tract length, and total radiation dose (mGy) also did not differ. S-PCNL was associated with lower ED (2.92 ± 0.32 mSv vs 5.3 ± 0.7 mSv, p = 0.0014) despite increased fluoroscopy time (86.32 ± 7.7 seconds vs 51.00 ± 5.1 seconds, p = 0.004), and was more likely a mini-PCNL (35.2% vs 15.9%, p = 0.032). In multivariate analysis, S-PCNL remained associated with reduced ED compared with P-PCNL (p = 0.002), whereas body mass index (p < 0.001) and staghorn calculi (p < 0.001) were independently associated with increased ED. We demonstrated that ED in US-guided PCNL is increased in the prone position compared with supine position, and in overweight patients regardless of position. US-guided S-PCNL may decrease radiation exposure to patients and surgeons compared with US-guided P-PCNL.
More Related Videos
03:56A Two-Step Method for Percutaneous Transhepatic Choledochoscopic Lithotomy
Published on: September 13, 2022
06:39Technical Modification of the Terminal Ureter During Total Transperitoneal Laparoscopic Nephroureterectomy for Upper Urinary Tract Urothelial Carcinoma
Published on: November 22, 2019
Related Concept Videos
Urinary Tract Calculi VI: Surgical Management
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Imaging Studies VII: Vascular Imaging