Related Experiment Video
Updated: Nov 9, 2025

Waste Water Derived Electroactive Microbial Biofilms: Growth, Maintenance, and Basic Characterization
Published on: December 29, 2013
Structure and indicators of electric energy consumption in dairy wastewater treatment plant
Radosław Żyłka1, Beata Karolinczak2, Wojciech Dąbrowski3
1Bielmlek Dairy Cooperative, Wojska Polskiego 52, 17-100 Bielsk Podlaski, Poland.
Abstract:
The aim of the research was to determine the indicators of electricity consumption in every stage of the dairy sewage treatment process in relation to the sewage flow and the load of removed organics (BOD5, COD) and nutrients (TN, TP). The research was conducted in a dairy wastewater treatment plant (WWTP) consisting of mechanical treatment, averaging tank, dissolved air flotation (DAF) and biological treatment with sequence batch reactors (SBRs). Energy consumption was measured with the help of transducers. Indicators of unit electricity consumption were determined on the basis of 95 measurement series of energy consumption, sewage flow and removed load. The mean value of total unit energy consumption relating to the flow for the entire WWTP was 2.29 kWh·m-3, while for biological treatment 1.17 kWh·m-3 and 0.05 kWh·m-3 for DAF. The mean values of indicators relating to removed pollutants load for the entire WWTP were: 1.89 kWh·kgrem BOD5-1, 1.30 kWh·kgrem COD-1, 48.61 kWh·kgrem TN-1 and 160.01 kWh·kgrem TP-1. During biological treatment, energy consumption indicators were on average: 1.65 kWh·kgrem BOD5-1 and 1.19 kWh·kgrem COD-1, 52.90 kWh·kgrem TN-1 and 141.26 kWh·kgrem TP-1, while for DAF: 0.12 kWh·kgrem BOD5-1, 0.09 kWh·kgrem COD -1, 3.85 kWh·kgrem TN-1 and 16.17 kWh·kgrem TP-1. It was found that the biological treatment in SBRs was responsible for 54.1% of the total energy consumption of dairy WWTP. Aerobic sewage sludge treatment accounted for 17.0% of total consumption, mechanical treatment 17.1%, deodorization 2.6%, and other (social, lighting etc.) 6.9%, while DAF only 2.3%. The real-time electricity metering system enabled the optimisation of the electricity consumption in the WWTP, taking into account its consumption in unit processes and the removed pollutants load. The application of this system enabled to make corrections that reduced energy consumption while maintaining the required treatment efficiency.
More Related Videos
11:31Continuously-stirred Anaerobic Digester to Convert Organic Wastes into Biogas: System Setup and Basic Operation
Published on: July 13, 2012
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
Related Concept Videos
Electrical Energy
Energy and Power Signals
Power Distribution in Three-phase and Single Phase Circuits
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...
Secondary Distribution