Related Experiment Video
Updated: Nov 9, 2025

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Evaluation of Radicular Dentin Microcracks Formation after Instrumentation with NiTi Hand and Rotary File System: A
Ajay Kumar1, Shalan Kaul2, Feby Kuriakose3
1Department of Conservative Dentistry and Endodontics, Indira Gandhi Government Dental College and Hospital, Jammu, India.
Aim And Objective:
The present study aimed to assess the formation of microcracks in root dentin post-instrumentation with nickel-titanium (NiTi) hand and rotary file system.
Materials And Methods:
Totally, 80 freshly extracted mandibular premolar teeth with single roots were chosen for this study. Access opening was performed and #10 K-file was used to attain patency of canal. All specimens were divided into four groups (each group having 20 specimens), i.e., Group I: Unprepared, Group II: NiTi hand K-files, Group III: Self-adjusting file, and Group IV: XP-Shaper single file. Complete irrigation of all the canals was performed after instrumentation. All roots were cut horizontally at three levels [apical third (3 mm), middle third (6 mm), and cervical third (9 mm)] from the apex with diamond disc. A stereomicroscope was used to view the sections under 20× magnification.
Results:
Self-adjusting file showed least number of defects with a percentage of 75% followed by XP-Shaper and NiTi hand K-files with a values of 65 and 60%, respectively. Use of hand K-files resulted in greater number of incomplete cracks (30%) and use of XP-Shaper demonstrated greater number of craze lines (15%). A statistically significant difference was found between the experimental groups in the formation of dentinal defects of root at apical third (3 mm) (p < 0.031) and middle third (6 mm) (p < 0.001), whereas the sections at cervical third (9 mm) did not show any statistically significant difference (p > 0.312).
Conclusion:
The present study concluded that the self-adjusting file system gives promising better results in cleaning ability with minimal incidence of radicular dentin microcracks than XP-Shaper and NiTi hand K-files system.
Clinical Significance:
The root dentin may unavoidably get damaged during instrumentation resulting in the formation of dentinal cracks and tiny complicated fractures, thus leading to endodontic failures. Various factors cause dentinal cracks, but the flexibility of file due to heat treatment, kinematics of the file, and the basic architecture of the file are the most significant ones. Self-adjusting file system represented satisfactory results with minimal microcracks defects.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
06:16Author Spotlight: Establishing an Accurate Microhardness Testing Protocol for Craniofacial Tissues
Published on: April 26, 2024