Signal averaged ECG in patients with early repolarization
Mani Hassanzadeh1, Ehsan Mardani1, Alireza Hosseinpour2
1Shiraz University of Medical Sciences Shiraz Iran.
Background:
Early repolarization (ER) pattern is diagnosed when the J-point is elevated on the patient's electrocardiogram. The aim of this study was to evaluate signal-averaged electrocardiography (SAECG) in patients with ER pattern.
Methods:
Subjects were divided into three groups: 1-patients with normal ECG pattern (control group); 2-patients with J-point elevation in the inferior leads; and 3-patients with J-point elevation in non-inferior leads.
Results:
The mean filtered QRS duration in groups with J-point elevation in inferior leads and non-inferior leads and in the control, was 86.4 ± 23.4 msec, 84.8 ± 26.6 msec, and 85.8 ± 24.8 msec, respectively, indicating no significant difference across the three groups. The mean duration of terminal QRS < 40µV was 21.2 ± 4.2 msec, 22.8 ± 4.6 msec, and 23.1 ± 4.5 msec in the mentioned groups, respectively, without a significant difference between the groups. Additionally, the mean root-mean-square voltage of terminal 40 msec was 34.5 ± 8.3 µV, 35.3 ± 8.6µV, and 35.7 ± 9.2 µV in patients with increased J-point in inferior leads, non-inferior leads, and the control group, respectively, showing no difference between the groups.
Conclusion:
In conclusion, we found that parameters in SAECG did not have any significant difference between patients with ER pattern and healthy individuals. Moreover, we concluded that SAECG cannot distinguish the patients with elevated J-point in inferior leads from non-inferior leads. Overall, SAECG does not appear to be a reliable diagnostic tool for the assessment of ER pattern.
More Related Videos
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...