On-line monitoring of water quality with a floating microbial fuel cell biosensor: field test results
Related Experiment Video
Updated: Nov 9, 2025

Self-standing Electrochemical Set-up to Enrich Anode-respiring Bacteria On-site
Published on: July 24, 2018
Ademola Adekunle1, Carrie Rickwood2, Boris Tartakovsky3
1National Research Council of Canada, 6100 Royalmount Ave, Montreal, QC, H4P 2R2, Canada. Ademola.Adekunle@cnrc-nrc.gc.ca.
Abstract:
Real-time biomonitoring using microbial fuel cell (MFC) based biosensors have been demonstrated in several laboratory studies, but field validation is lacking. This study describes the long-term performance of an MFC based biosensor developed for real-time monitoring of changes in the water quality of a metal-contaminated stream. After a startup in the laboratory, biosensors were deployed in a stream close to an active mining complex in Sudbury, ON, Canada. Three sites within the stream were selected for biosensors installation based on their positions relative to the mining complex discharge points - upstream (lowest heavy metals concentration), midpoint and downstream. The biosensors installed at these sites were able to detect, in real-time, temporal changes in the water quality over a 2-month period. The biosensor response was confirmed by the results of a conventional toxicity assay (48-h acute Daphnia magna) as well as analytical measurements of heavy metals concentration in the stream. We conclude that the biosensor could detect changes in the overall water quality of the stream despite the uncontrolled situations typical for field operations as compared to laboratory conditions. To further explain the results observed during the field test, the rapid Microtox bioassay and D. magna assay were used to investigate the possible contributions of the two dominant mining metals (Nickel and Copper) to water toxicity in the test area.
More Related Videos
11:58Waste Water Derived Electroactive Microbial Biofilms: Growth, Maintenance, and Basic Characterization
Published on: December 29, 2013
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016