Deep convolutional autoencoder for the simultaneous removal of baseline noise and baseline drift in chromatograms
Alexander Kensert1, Gilles Collaerts2, Kyriakos Efthymiadis3
1University of Leuven (KU Leuven), Department for Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, 3000 Leuven, Belgium; Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussel, Belgium.
Abstract:
Enhancement of chromatograms, such as the reduction of baseline noise and baseline drift, is often essential to accurately detect and quantify analytes in a mixture. Current methods have been well studied and adopted for decades and have assisted researchers in obtaining reliable results. However, these methods rely on relatively simple statistics of the data (chromatograms) which in some cases result in significant information loss and inaccuracies. In this study, a deep one-dimensional convolutional autoencoder was developed that simultaneously removes baseline noise and baseline drift with minimal information loss, for a large number and great variety of chromatograms. To enable the autoencoder to denoise a chromatogram to be almost, or completely, noise-free, it was trained on data obtained from an implemented chromatogram simulator that generated 190.000 representative simulated chromatograms. The trained autoencoder was then tested and compared to some of the most widely used and well-established denoising methods on testing datasets of tens of thousands of simulated chromatograms; and then further tested and verified on real chromatograms. The results show that the developed autoencoder can successfully remove baseline noise and baseline drift simultaneously with minimal information loss; outperforming methods like Savitzky-Golay smoothing, Gaussian smoothing and wavelet smoothing for baseline noise reduction (root mean squared error of 1.094 mAU compared to 2.074 mAU, 2.394 mAU and 2.199 mAU) and Savitkzy-Golay smoothing combined with asymmetric least-squares or polynomial fitting for baseline noise and baseline drift reduction (root mean absolute error of 1.171 mAU compared to 3.397 mAU and 4.923 mAU). Evidence is presented that autoencoders can be utilized to enhance and correct chromatograms and consequently improve and alleviate downstream data analysis, with the drawback of needing a carefully implemented simulator, that generates realistic chromatograms, to train the autoencoder.
More Related Videos
06:03AMEBaS: Automatic Midline Extraction and Background Subtraction of Ratiometric Fluorescence Time-Lapses of Polarized Single Cells
Published on: June 23, 2023
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...