Alexandra Gogola1, Davneet S Minhas1, Victor L Villemagne2
1Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania.
Abstract:
Tau PET tracers exhibit varying levels of specific signal and distinct off-target binding patterns that are more diverse than amyloid PET tracers. This study compared 2 frequently used tau PET tracers, 18F-flortaucipir and 18F-MK-6240, in the same subjects. Methods:18F-flortaucipir and 18F-MK-6240 scans were collected within 2 mo in 15 elderly subjects varying in clinical diagnosis and cognition. FreeSurfer, version 5.3, was applied to 3-T MR images to segment Braak pathologic regions (I-VI) for PET analyses. Off-target binding was assessed in the choroid plexus, meninges, and striatum. SUV ratio (SUVR) outcomes were determined over 80-100 min (18F-flortaucipir) or 70-90 min (18F-MK-6240) normalized to cerebellar gray matter. Masked visual interpretation of images was performed by 5 raters for both the medial temporal lobe and the neocortex, and an overall (majority) rating was determined. Results: Overall visual ratings showed complete concordance between radiotracers for both the medial temporal lobe and the neocortex. SUVR outcomes were highly correlated (r2 > 0.92; P ≪ 0.001) for all Braak regions except Braak II. The dynamic range of SUVRs in target regions was approximately 2-fold higher for 18F-MK-6240 than for 18F-flortaucipir. Cerebellar SUVs were similar for 18F-MK-6240 and 18F-flortaucipir, suggesting that differences in SUVRs are driven by specific signals. Apparent off-target binding was observed often in the striatum and choroid plexus with 18F-flortaucipir and most often in the meninges with 18F-MK-6240. Conclusion: Both 18F-MK-6240 and 18F-flortaucipir are capable of quantifying signal in a common set of brain regions that develop tau pathology in Alzheimer disease; these tracers perform equally well in visual interpretations. Each also shows distinct patterns of apparent off-target binding. 18F-MK-6240 showed a greater dynamic range in SUVR estimates, which may be an advantage in detecting early tau pathology or in performing longitudinal studies to detect small interval changes.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
10:20Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET