Related Experiment Video
Updated: Nov 8, 2025

Controlled Synthesis and Fluorescence Tracking of Highly Uniform PolyN-isopropylacrylamide Microgels
Published on: September 8, 2016
MRI diffusion phantoms: ADC and relaxometric measurement comparisons between polyacrylamide and agarose gels
T Boursianis1, G Kalaitzakis1, E Pappas2
1Department of Medical Physics, University of Crete, Heraklion, Crete, Greece.
Purpose:
The aim of this study is to compare polyacrylamide and agarose gels, as components of a simple MRI phantom, for the measurements of Apparent Diffusion Coefficient (ADC), T1 and T2 relaxation times.
Materials And Methods:
Five (5) test tubes with polyacrylamide gels of different monomer concentrations and six (6) test tubes of different agarose gel concentrations were used as a phantom for ADC, T1 and T2 measurements, which were expressed as 2D color parametric maps, on a 1.5 T clinical MRI system. ADC and T2 maps were calculated utilizing a Weighted Linear (WL) regression fitting algorithm. T1 maps were calculated utilizing a standard non-linear fitting algorithm.
Results:
In agarose gels, ADC measurements are independent of the agarose concentration, whereas the T1 and T2 relaxation times decrease with increasing agarose concentration. On the contrary, in polyacrylamide gels, ADC measurements decrease quadratically while increasing the monomer concentration, whereas the T1 and T2 relaxation times reveal a linear decrease with increasing monomer concentration.
Conclusion:
Polyacrylamide gels can serve as a better means for simulating ADC values, as compared with the agarose gels used in this study.
Related Concept Videos
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...