Related Experiment Video
Updated: Nov 8, 2025

Automation of the Micronucleus Assay Using Imaging Flow Cytometry and Artificial Intelligence
Published on: January 27, 2023
The 3D reconstructed skin micronucleus assay using imaging flow cytometry and deep learning: A proof-of-principle
Ashley Allemang1, Robert Thacker2, Richard A DeMarco2
1Procter & Gamble, Mason Business Center, Mason, OH, USA.
Abstract:
The reconstructed skin micronucleus (RSMN) assay was developed in 2006, as an in vitro alternative for genotoxicity evaluation of dermally applied chemicals or products. In the years since, significant progress has been made in the optimization of the assay, including publication of a standard protocol and extensive validation. However, the diverse morphology of skin cells makes cell preparation and scoring of micronuclei (MN) tedious and subjective, thus requiring a high level of technical expertise for evaluation. This ultimately has a negative impact on throughput and the assay would benefit by the development of an automated method which could reduce scoring subjectivity while also improving the robustness of the assay by increasing the number of cells that can be scored. Imaging flow cytometry (IFC) with the ImageStream®X Mk II can capture high-resolution transmission and fluorescent imagery of cells in suspension. This proof-of-principle study describes protocol modifications that enable such automated measurement in 3D skin cells following exposure to mitomycin C and colchicine. IFC was then used for automated image capture and the Amnis® Artificial Intelligence (AAI) software permitted identification of binucleated (BN) cells with 91% precision. On average, three times as many BN cells from control samples were evaluated using IFC compared to the standard manual analysis. When IFC MNBN cells were visually scored from within the BN cell images, their frequency compared well with manual slide scoring, showing that IFC technology can be applied to the RSMN assay. This method enables faster time to result than microscope-based scoring and the initial studies presented here demonstrate its capability for the detection of statistically significant increases in MNBN frequencies. This work therefore demonstrates the feasibility of combining IFC and AAI to automate scoring for the RSMN assay and to improve its throughput and statistical robustness.
More Related Videos
12:56An Automated Method to Perform The In Vitro Micronucleus Assay using Multispectral Imaging Flow Cytometry
Published on: May 13, 2019
06:34SCAnED - An Open-source Skin Segmentation Macro for Semi-automated Cell and Nuclei Detection in Epidermal and Dermal Skin Compartments
Published on: August 8, 2025