Related Experiment Video
Updated: Nov 8, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Respiratory variability of inferior vena cava at different mechanical ventilator settings
Ebru Unal Akoglu1, Hasan Demir2, Tuba Cimilli Ozturk1
1Fatih Sultan Mehmet Training and Research Hospital, Department of Emergency Medicine, Istanbul, Turkey.
Background:
Assessment of the respiratory changes of the inferior vena cava (IVC) diameter have been investigated as a reliable tool to estimate the volume status in mechanically ventilated and spontaneously breathing patients. Our purpose was to compare the echocardiographic measurements the IVC diameter, stroke volume and cardiac output in different positive pressure ventilation parameters.
Methods:
This prospective clinical study with crossover design was conducted in the Intensive Care Unit (ICU). Twenty-five sedated, paralyzed, intubated, and mechanically ventilated patients with volume control mode (CMV) in the ICU due to respiratory failure were included in the study. Positive End-Expiratory Pressure (PEEP) and Tidal Volume (TV) were changed in each patient consecutively (Group A: TV 6 ml/kg, PEEP 5 cmH20, B: TV 6, PEEP 8, C: TV 8, PEEP 5, D: TV 8, PEEP 8) and the changes in vital parameters, central venous pressure (CVP) and ultrasonographic changes in IVC and cardiac parameters were measured. All measures were compared between groups by robust repeated measures ANOVA with trimmed mean.
Results:
The respiratory changes of the IVC diameter and echocardiographic parameters showed no significant difference in separate mechanical ventilator settings. Significant difference was found in peak and plateau pressure values among groups (p < 0.05).
Conclusion:
The results of our study suggest that IVC related parameters are not affected with different ventilatory settings. Further studies are needed to confirm the reliability of these parameters as a predictor of fluid assessment.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...