Abstract:
A robust finite-time control (FTC) framework using continuous terminal sliding-mode control (SMC) and high-order sliding-mode observer (HOSMO) is discussed to realize the trajectory tracking of flexible-joint robots in this article. Control performances of the robots always suffer from unknown matched and mismatched time-varying disturbances. Traditional SMC exists with a chattering phenomenon and cannot cope with mismatched time-varying disturbances due to its inherent structure property. For this reason, two HOSMOs are devised to estimate the time-varying disturbances on the link and motor side, respectively. Then, by fusing the states and disturbance estimations into a novel terminal sliding-mode surface, a continuous robust FTC scheme is developed. The proposed control strategy can not only handle both matched and mismatched time-varying disturbances but also obtain a finite-time convergence performance. The rigorous finite-time stability analysis of the closed-loop system under the proposed control method is guaranteed. The results are illustrated to verify the effectiveness and robustness of the proposed design approach.
Related Concept Videos
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
RLC Circuit as a Damped Oscillator
Consider a series RLC circuit. Here, the presence of resistance in the circuit leads to energy loss due to joule heating in the resistance. Therefore, the total electromagnetic energy in the circuit is no longer constant and decreases with time. Since the magnitude of charge, current, and potential difference continuously decreases, their oscillations are said to be damped. This is...
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Phase-lead and Phase-lag Controllers
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from...
Transfer Function in Control Systems
To derive the transfer function, consider a general nth-order linear time-invariant...