Abstract:
The current study evaluates the effect of seawater physico-chemical characteristics on the relationship between the concentration of metals measured by Diffusive Gradients in Thin films (DGT) passive samplers (i.e., DGT-labile concentration) and the concentrations measured in discrete water samples. Accordingly, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used to measure the total dissolved metal concentrations in the discrete water samples and the labile metal concentrations obtained by DGT samplers; additionally, lead and cadmium conditional labile fractions were determined by Anodic Stripping Voltammetry (ASV) and total dissolved nickel was measured by Cathodic Stripping Voltammetry (CSV). It can be concluded that, in general, the median ratios of DGT/ICP and DGT/ASV(CSV) were lower than 1, except for Ni (median ratio close to 1) and Zn (higher than 1). This indicates the importance of speciation and time-integrated concentrations measured using passive sampling techniques, which is in line with the WFD suggestions for improving the chemical assessment of waterbodies. It is the variability in metal content in waters rather than environmental conditions to which the variability of the ratios can be attributed. The ratios were not significantly affected by the temperature, salinity, pH, oxygen, DOC or SPM, giving a great confidence for all the techniques used. Within a regulatory context such as the EU Water Framework Directive this is a great advantage, since the simplicity of not needing to use corrections to minimize the effects of environmental variables could help in implementing DGTs within monitoring networks.
More Related Videos
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...