Fast-acting insulin aspart (Fiasp®) improves glycemic outcomes when used with MiniMedTM 670G hybrid closed-loop
Benyamin Grosman1, Di Wu1, Neha Parikh1
1Medtronic Diabetes, United States.
Introduction:
Medtronic has developed a virtual patient simulator for modeling and predicting insulin therapy outcomes for people with type 1 diabetes (T1D). An enhanced simulator was created to estimate outcomes when using the MiniMedTM 670G system with standard NovoLog® (EU: NovoRapid, US: NovoLog) versus Fiasp ® by using clinical data.
Methods:
Sixty-seven participants' PK profiles were generated per type of insulin (Total of 134 PK profiles). 7,485 virtual patients' PK measurements was matched with one of the 67 NovoLog® PK Tmax values. These 7,485 virtual patients were then simulated using the Medtronic MiniMed™ 670G algorithm following an in-silico protocol of 90 days: 14 days in open loop (Manual Mode) followed by 76 days in closed loop (Auto Mode). Simulation study was repeated with each NovoLog® PK profile being replaced by its corresponding Fiasp® PK profile in the same virtual patient. To validate our in-silico analysis, we compared the results of "actual" 19 "real life" patients from a clinical study RESULTS: Simulated overall and postprandial glycemic outcomes improved in all age groups with Fiasp®. The percentage of time in the euglycemic range increased by about ~2.2% with Fiasp®, in all age groups (p < 0.01). The percentage of time spent at <70 mg/dL was reduced by about ~0.6% with insulin Fiasp® (p < 0.01) and the mean glucose was reduced by about 1.3 mg/dL (p < 0.01), excluding those age <7 years. The simulated mean postprandial SG was reduced by ~5 mg/dL, a significant difference for all age groups. A clinical study results showed similar improvements with MiniMedTM 670G system when switching from NovoLog® to Fiasp®.
Conclusions:
The simulation studies indicate that using Fiasp® in place of NovoLog® with the MiniMedTM 670G system will significantly improve the time spent in the healthy, euglycemic range and reduce exposure to hyperglycemia and hypoglycemia in most patients.
Related Concept Videos
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Oral Hypoglycemic Agents: Glinides
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...
Dipeptidyl Peptidase 4 Inhibitors