Related Experiment Video
Updated: Nov 8, 2025

Assessment of Bone Fracture Healing Using Micro-Computed Tomography
Published on: December 9, 2022
Comparison of diagnosis of cracked tooth using contrast-enhanced CBCT and micro-CT
ZiYang Hu1, TieMei Wang1, Xiao Pan1
1Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China.
Objectives:
To evaluate the diagnostic accuracy using sodium iodide (NaI) and dimethyl sulfoxide (DMSO) as contrast agent in cone beam computed tomography (CBCT) scanning, and compare this with micro-CT.
Methods:
18 teeth were cracked artificially by soaking them cyclically in liquid nitrogen and hot water. After pre-treatment with artificial saliva, the teeth were scanned in four modes: CBCT routine scanning without contrast agent (RS); CBCT with meglumine diatrizoate (MD) as contrast agent (ES1); CBCT with NaI + DMSO as contrast agent (ES2); and micro-CT (mCT). The number of crack lines was evaluated in all four modes. Depth of crack lines and number of cracks presented from the occlusal surface to the pulp cavity (Np) in ES2 and micro-CT images were evaluated.
Results:
There were 63 crack lines in all 18 teeth. 45 crack lines were visible on ES2 images as against four on the RS and ES1 images (p<0.05) and 37 on micro-CT images (p>0.05). Further, 34 crack lines could be observed on both ES2 and micro-CT images, and the average depth presented on ES2 images was 4.56 ± 0.88 mm and 3.89 ± 1.08 mm on micro-CT images (p<0.05). More crack lines could be detected from the occlusal surface to the pulp cavity on ES2 images than on micro-CT images (22 vs 11).
Conclusion:
CBCT with NaI +DMSO as the contrast agent was equivalent to micro-CT for number of crack lines and better for depth of crack lines. NaI + DMSO could be a potential CBCT contrast agent to improve diagnostic accuracy for cracked tooth.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
X-ray Imaging