Related Experiment Video
Updated: Nov 8, 2025

Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
[Blood pressure and heart rate changes of 640 single dental implant surgeries]
1Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Objective:
To investigate the blood pressure and heart rate changes and influencing factors during single dental implant surgery.
Methods:
A retrospective cohort study was conducted. Six hundred and forty cases underwent single dental implant placement in Department of Prosthodontics, Peking University School and Hospital of Stomatology from January 2016 to December 2016 were recruited in this study according to the inclusion and exclusion criteria. They were divided into different groups according to the exposure factors which were patient characteristics (gender, age) and surgical procedures (immediate placement, flap elevation, bone grafting). The correlation between blood pressure and heart rate variability during single dental implant surgery and the patient characteristics and surgical procedures were analyzed.
Results:
The average systolic blood pressure variability was 9.47%±6.45% (maximum 46.04%), the average diastolic blood pressure variability was 12.18%±9.39% (maximum 88.00%), and the average heart rate variability was 10.59%±7.68% (maximum 49.12%). The effects of age and bone grafting on blood pressure variability, and of gender and immediate placement on heart rate variability, were statistically significant (P < 0.05), respectively. The incidence of abnormal intraoperative blood pressure rise was 4.69%, of which there were 4 cases (0.63%) of systolic blood pressure ≥180 mmHg and/or diastolic blood pressure ≥110 mmHg. The incidence of abnormal intraoperative heart rate rise was 6.72%. Hierarchical analysis showed a higher risk of abnormal intraoperative blood pressure rise in the elderly (≥60 years) male patients [P < 0.05, RR=3.409 (95%CI: 1.155-10.062) ] and flap elevation with bone grafting cases [P < 0.05, RR=2.382 (95%CI: 1.126-5.040)], respectively. There was no statistically significant association between abnormal heart rate rise and patient characteristics or surgical procedures (P>0.05).
Conclusion:
There was a certain risk of blood pressure and heart rate variability during dental implant surgery. Elderly male patients and flap elevation with bone grafting were risk factors of abnormal intraoperative blood pressure rise.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Aneurysm IV: Nursing Management
Pre-Procedural Guidelines for Assessing Blood Pressure