Related Experiment Video
Updated: Nov 8, 2025

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Axillary Thermometry Demonstrates Greater Reliability Compared With Rectal Thermometry in Healthy Neonates
Ketan Prakash Nadkarni1, Zachary Mayo2, Jeffrey P Laux3
1Atrium Health, Charlotte, NC, USA.
Abstract:
Rectal thermometry (RT) is considered the gold standard for measuring temperature in newborns, despite increasing use of temporal artery thermometry (TT) and axillary thermometry (AT) methods. Few prospective studies compare RT, TT, and AT in a newborn nursery setting. To determine the accuracy and reliability of these methods, we enrolled 205 healthy, full-term newborns. TT displayed higher mean temperatures than RT by 0.25 °F (standard error [SE] = 0.04, P < .001). AT and RT measurements did not significantly differ, with their means differing only by 0.02 °F (SE = 0.04, P = .87). For reliability, RT measurements differed by 0.45 °F (SE = 0.03) in either direction of the models' predicted mean for each subject. AT and TT measurements varied much less from their predicted means 0.32 °F (SE = 0.02) and 0.34 °F (SE = 0.02), respectively (both P < .001). Assuming mean RT is correct, TT is less accurate than AT. RT showed poor reliability between measurements. AT is an accurate and reliable method of temperature screening in healthy neonates.
More Related Videos
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
08:16Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...