Related Experiment Video
Updated: Nov 8, 2025

Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer
Published on: February 12, 2022
SP rTaTME: initial clinical experience with single-port robotic transanal total mesorectal excision (SP rTaTME)
J H Marks1, J F Salem2, P Adams2
1Lankenau Medical Center Division of Colorectal Surgery, Marks Colorectal Surgical Associates, Wynnewood, PA, USA. marksj@mlhs.org.
Background:
The technical difficulty and steep learning curve of transanal total mesorectal excision (taTME) has limited widespread adoption. The single-port (SP) daVinci robot is designed to facilitate single-incision and natural-orifice transluminal endoscopic surgery (NOTES). This paper describes the first clinical experience of single-port robotic taTME (SP rTaTME).
Methods:
This was a prospective study on consecutive patients with rectal cancer who underwent SP rTaTME proctosigmoidectomy with handsewn coloanal anastomosis in December 2018 and January 2019. The primary outcome was technical feasibility of the procedure. The secondary outcomes include blood loss, intraoperative complications, length of hospital stay, quality of the TME specimen, short- and long-term morbidity and mortality, as well as short-term oncologic follow -up.
Results:
There were two patients, a 48-year-old male and a 38-year-old female. Both operations were completed successfully without complications or conversion. Estimated blood loss was 200 mL and 130 mL. In both cases the TME was completed transanally using the SP robot. In the first patient, the abdominal portion was completed through an abdominal single-incision; in the second patient the operation was entirely performed transanally as a pure NOTES procedure. In both cases, the final pathology report showed a complete TME with negative margins. Patients were discharged on postoperative day 3 and 4,respectively. There was no long-term morbidity or mortality.
Conclusions:
SP rTaTME is feasible and can be safely performed. It provides excellent optics and dexterity to work in a limited space. Future studies are required to further define the safety profile and the ultimate utility of the SP robot for taTME.
More Related Videos
07:22Surgical Robot-Assisted Transanal Specimen Extraction Radical Sigmoidectomy Without an Auxiliary Abdominal Incision
Published on: June 13, 2025
08:26Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction