Related Experiment Video
Updated: Nov 8, 2025

Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
Published on: August 18, 2017
Optimizing Chiral Selectivity in Practical Life-Detection Instruments
Ling Zhang1,2,3,4, Fanjiang Zeng1,2,3,4, Christopher P McKay5
1State Key Laboratory of Desert and Oasis Ecology, Xinjiang Institute of Ecology and Geography, Chinese Academy of Sciences, Urumqi, China.
Abstract:
Preferential uptake of either levorotatory (L) or dextrorotatory (D) enantiomer of a chiral molecule is a potential planetary life-detection method. On Earth, bacteria, as a rule, metabolize D-sugars and L-amino acids. Here, we use growth experiments to identify exceptions to the rule and their potential impact on the method's reliability. Our experiments involve six strains of Bacillus and collective uptake of the sugars glucose and arabinose, and the amino acids alanine, glutamic acid, leucine, cysteine, and serine-all of which are highly soluble. We find that selective uptake is not evident unless (1) each sugar is tested individually and (2) multiple amino acids are tested together in a mixture. Combining sugars should be avoided because, as we show in Bacillus bacteria, the same organisms may catabolize one sugar, glucose, in D-form and another sugar, arabinose, in L-form. Single amino acids should be avoided because bacteria can access certain proteinogenically incompatible enantiomers using specific racemases. Specifically, bacteria contain an alanine acid racemase and can catabolize D-alanine if no other D-amino acids are present. The proposed improvements would reliably separate nonselective chemical reactions from biological reactions and, if life is indicated, inform whether the selective patterns for amino acids and sugars are the same as on Earth.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chirality in Nature
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Properties of Enantiomers and Optical Activity
Measuring Reaction Rates

