Can We Trust the Math? Correlation of Objective Postvoid Residual With Calculated Subtraction Postvoid Residual

Sierra M Jansen, Abbi Woll1, Heidi W Brown2

  • 1Department of Obstetrics and Gynecology, Medical University of South Carolina, Charleston, SC.

Summary

Calculating postvoid residual (PVR) by subtraction is less accurate than objective measurement in postoperative patients. Objective PVR measurement is preferred to avoid misclassifying urinary retention, especially after urogynecologic surgery.

Related Concept Videos

Urodynamic Studies: Uroflowmetry01:19

Urodynamic Studies: Uroflowmetry

Uroflowmetry is a non-invasive urodynamic test designed to measure various aspects of urination, including volume, flow rate, and the time to void. This test is crucial for diagnosing and assessing conditions such as bladder outlet obstruction, bladder dysfunction, incomplete bladder emptying, incontinence, and urinary tract blockages caused by benign prostatic hyperplasia (BPH) and urethral strictures.Pre-Test Instructions:Before a uroflowmetry test, patients are typically advised to drink...
1.4K
Residuals and Least-Squares Property01:11

Residuals and Least-Squares Property

The vertical distance between the actual value of y and the estimated value of y. In other words, it measures the vertical distance between the actual data point and the predicted point on the line
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
8.2K
Imaging Studies VI: Voiding Cystourethrography and Cystography01:22

Imaging Studies VI: Voiding Cystourethrography and Cystography

Voiding Cystourethrography (VCUG) and Cystography are specialized radiographic procedures used to examine the structure and function of the bladder and urethra.Voiding Cystourethrography (VCUG)A Voiding Cystourethrogram (VCUG) is a diagnostic imaging procedure that assesses the anatomy and function of the lower urinary tract. It focuses on the bladder, bladder neck, and urethra, helping detect abnormalities such as vesicoureteral reflux (VUR)—the backward or reverse flow of urine into the...
392
Residual Plots01:07

Residual Plots

A residual plot is a statistical representation of data used to analyze correlation and regression results. It helps verify the requirements for drawing specific conclusions about correlation and regression. To obtain the residual plot, first, the residual for each data value is calculated, which is simply the vertical distance between the observed and the predicted value obtained from the regression equation.
When the residual values are plotted against the variable x, it is called a residual...
5.3K
Determination of Renal Drug Clearance: Graphical and Midpoint Methods01:07

Determination of Renal Drug Clearance: Graphical and Midpoint Methods

Renal clearance, a crucial parameter in pharmacokinetics, can be determined using two different methods: the graphical method and the midpoint method. These methods provide insights into the rate of drug excretion by the kidneys and aid in assessing renal function.
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
251
One-Compartment Open Model: Urinary Excretion Data and Determination of k01:11

One-Compartment Open Model: Urinary Excretion Data and Determination of k

The one-compartment open model leverages urinary excretion data to estimate renal clearance, which gauges the kidney's capacity to expel a drug. This method offers several benefits, including directly measuring drug elimination and assessing the kidney's contribution to overall drug clearance. However, this approach has limitations. It assumes sole renal excretion of the drug, which is not true for all drugs. Accurate urinary excretion and plasma drug concentration measurement can also...
402