Related Experiment Video
Updated: Nov 8, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Automatic segmentation for ultrasound image of carotid intimal-media based on improved superpixel generation
Shuxin Zhuang1, Fenlan Li2, Alex Noel Joseph Raj1
1Key Laboratory of Digital Signal and Image Processing of Guangdong Province, Shantou University, Shantou, Guangdong, China; Department of Electronic Engineering, Shantou University, Shantou, Guangdong, China.
Objective:
Carotid atherosclerosis (CAS) is the main reason leading to cardiovascular conditions such as coronary heart disease and cerebrovascular diseases. In the carotid ultrasound images, the carotid intima-media structure can be observed in an annular narrow strip, which its inner contour corresponds to the carotid intima, and the outer contour corresponds to the carotid extima. With the development of carotid atherosclerosis, the carotid intima-media will gradually thicken. Therefore, doctors can observe the carotid intima-media so as to obtain the pathological changes of the internal structure of the patient's carotid arteries. However, due to the presence of artifacts and noises the quality of the ultrasound images are degraded, making it difficult to obtain accurate carotid intima-media structures. This article presents a novel self-adaptive method to enable obtaining the carotid intima-media through carotid intima/extima segmentation.
Method:
After preprocessing the ultrasound images by homomorphic filtering and median filtering, we propose an improved superpixel generation algorithm that employs the fusion of gray-level and luminosity-based information to decompose the image into numerous superpixels and later presents the carotid intima. Meanwhile, based on the features of the carotid artery, the initial position of the carotid extima is located by the normalized cut algorithm and later the fractal theory is employed to segment the carotid extima.
Results:
The proposed method for segmenting carotid intima obtained mean values of the DICE true positive ratio (TPR), false positive ratio (FPR), precision scores of 97.797%, 99.126%, 0.540%, 97.202%, respectively. Further from the segmentation method of the carotid extima the performance measures such as mean DICE, TPR, accuracy, F-score obtained are 95.00%, 92.265%, 97.689%, 94.997%, respectively.
Conclusion:
Comparing with traditional methods, the proposed method performed better. The experimental results indicated that the proposed method obtained the carotid intima-media both automatically and accurately thus effectively assist doctors in the diagnosis of CAS.

